Decibel dB
Contents |
[edit] Introduction
Decibels (dB) are most commonly used as a measure of sound level, but they are also used in electronics, signals and communications.
Sound is a variation in pressure detectable by the ear, whereas noise is undesired sound, or any sound which causes disturbance or annoyance to the recipient. The unit used to describe sound wave intensity is the bel, named after the inventor Alexander Graham Bell. The human ear is sensitive enough to detect changes of as little as 1/10 of a bel, and so sound intensity levels are described in decibels.
Today it is nearly impossible to find a place in a town or city where there is absolute and total silence. There is simply too much traffic, too many people, factories, plants, railway stations, airports and so on. And yet noise pollution is proven to be detrimental to human health and safety. That is why permissible levels of sound emissions are under permanent control by various regulatory agencies. Any equipment used outside (vehicles, devices, machinery) should meet the requirements of the directives concerning noise and outdoor equipment.
Especially in residential neighborhoods, there are particular time periods when work by means of drills and other noisy equipment can be carried out. Even though these sounds are fleeting, their levels are extremely high for unprotected human ears and must be measured by a sound level meter to assess risk and prevent damaging exposure. Problems with noise levels also are experienced by those living in close proximity to railway stations, airports, busy streets, hospitals and fire and police stations. Excessive long-term exposure to high-level noise negatively impacts human health, resulting in hearing damage, raised nervousness, irritability and unstable psychological conditions. Thus, in some areas noise monitoring and control by use of a sound level meter is an essential and mandated task.
Noise levels between 120 dB and 150 dB (e.g., airplanes taking off and landing, drilling and sawing of roadways) are dangerous to human hearing and their continuous presence has dire consequences. Perfect noise levels are between 30 dB and 50 dB, though these pleasant levels are sometimes unreachable in today's society.
A sound wave’s intensity is the average amount of energy transmitted per unit time through a unit area in a specified direction. The sound intensity level, I, in decibels is 10 times the logarithm of the ratio of the intensity of a sound wave to a reference intensity:
[edit] The decibel scale
The decibel scale gives an approximation of human perception of relative loudness. This is because the human ear has a logarithmic response to changes in sound level.
On the decibel scale, the smallest audible sound (near total silence) is 0 dB. A sound ten times more powerful is 10 dB. A sound 100 times more powerful than near silence is 20 dB.
The logarithmic nature of the dB scale means that each 10 dB increase represents a 10-fold increase in acoustic power. A 20 dB increase is therefore a 100-fold increase in power, and a 30 dB increase is a 1000-fold increase. However, an increase in acoustic power of ten times does not mean that the sound is perceived as being ten times louder. The ear perceives a 10 dB increase in sound level as only a doubling of sound loudness, and a 10 dB decrease in sound level as a halving of sound loudness.
The lower threshold of human hearing is around 5 dB. Normally speaking voices are around 65 dB. A rock concert can be around 120 dB.
Sounds that are 85 dB or above can cause hearing damage, and the higher the sound pressure, the less time it takes to cause damage. For example, a sound of 85 dB may take 8 hours to cause damage, whereas a sound of 100 dB may start to cause damage after only 30 minutes. A sound of around 150 dB can cause instantaneous hearing damage.
[edit] Sound levels in construction
Those working in the construction industry are often exposed to an increased noise level. Some examples of construction equipment and their approximate decibel levels are shown below:
- Backhoe: 84-93 dB
- Bulldozer: 93-96 dB
- Concrete joint cutter: 99-102 dB
- Crane: 90-96 dB
- Earth tamper: 90-96 dB
- Earthmover: 87-94 dB
- Front-end loader: 86-94 dB
- Hammer: 87-95 dB
- Jackhammer: 102-111 dB
- Pneumatic chip hammer: 103-113 dB
- Portable saw: 88-102 dB
- Stud welder: 101 dB
The Control of Noise at Work Regulations 2005 requires that employers to take steps to reduce the harmful effects of noise on hearing. These relate to the levels of exposure to noise averaged by an employee over a working day or week and the maximum noise (peak sound pressure) to which they are exposed in a working day. There are two main action levels for continuous noise:
Lower exposure action value, at which the employer must make hearing protection available and provide information and training.
Upper exposure action value, above which the employer is required to take reasonably practicable measures to reduce noise exposure, such as engineering controls or other technical measures. If the noise cannot be controlled by these measures, hearing protection is mandatory.
Exposure limit value, levels of noise exposure which must not be exceeded.
[edit] Related articles on Designing Buildings
- Airborne sound.
- Approved Document E.
- Audio frequency.
- Building acoustics.
- Control of Noise at Work Regulations 2005.
- Environmental health.
- Equivalent continuous sound pressure level.
- Impact sound.
- Noise level.
- Robust details certification scheme.
- Room acoustics.
- Sound absorption.
- Sound frequency.
- Sound power level.
- Sound v noise.
- Structure-borne sound.
- Workplace noise exposure estimator.
[edit] External references
Featured articles and news
Twas the site before Christmas...
A rhyme for the industry and a thankyou to our supporters.
Plumbing and heating systems in schools
New apprentice pay rates coming into effect in the new year
Addressing the impact of recent national minimum wage changes.
EBSSA support for the new industry competence structure
The Engineering and Building Services Skills Authority, in working group 2.
Notes from BSRIA Sustainable Futures briefing
From carbon down to the all important customer: Redefining Retrofit for Net Zero Living.
Principal Designer: A New Opportunity for Architects
ACA launches a Principal Designer Register for architects.
A new government plan for housing and nature recovery
Exploring a new housing and infrastructure nature recovery framework.
Leveraging technology to enhance prospects for students
A case study on the significance of the Autodesk Revit certification.
Fundamental Review of Building Regulations Guidance
Announced during commons debate on the Grenfell Inquiry Phase 2 report.
CIAT responds to the updated National Planning Policy Framework
With key changes in the revised NPPF outlined.
Councils and communities highlighted for delivery of common-sense housing in planning overhaul
As government follows up with mandatory housing targets.
CIOB photographic competition final images revealed
Art of Building produces stunning images for another year.
HSE prosecutes company for putting workers at risk
Roofing company fined and its director sentenced.
Strategic restructure to transform industry competence
EBSSA becomes part of a new industry competence structure.
Major overhaul of planning committees proposed by government
Planning decisions set to be fast-tracked to tackle the housing crisis.
Industry Competence Steering Group restructure
ICSG transitions to the Industry Competence Committee (ICC) under the Building Safety Regulator (BSR).
Principal Contractor Competency Certification Scheme
CIOB PCCCS competence framework for Principal Contractors.
The CIAT Principal Designer register
Issues explained via a series of FAQs.